3good reasons
to create an account
save
visualize
stay informed
create your account
save/visualize/stay informed create your account
degremont® water handbook degremont® water handbook
Menu
Close
search
Close
login
  • FR
  • EN
  • FR
  • EN
  • water and generalities
    • water: a fundamental element
    • what water should we treat ? and why ?
    • fundamental physical-chemical engineering processes applicable to water treatment
    • fundamental biological engineering processes applicable to water treatment
    • water analysis and treatability
    • aquatic organisms
    • corrosion in metal and concrete
  • formulas and tools
    • formulary
  • processes and technologies
    • pre-treatments
    • flocculators – settling tanks – flotation units
    • biological processes
    • methane fermentation
    • filters
    • using ion exchangers
    • separation by membranes
    • degasification, odour control, evaporation
    • oxidation-disinfection
    • liquid sludge treatment
    • dewatered sludge treatment
    • reagent storage and feeding
    • instrumentation control-regulation
    • drinking water treatment
    • treating municipal wastewater
    • treatment and conditioning of industrial water
    • industrial processes and effluent treatment
  • degremont® technologies
    • drinking water production
    • desalination
    • wastewater treatment
    • sludge treatment
    • air treatment
  • case studies
    • drinking water production
    • wastewater treatment
    • desalination
    • sludge treatment
  • login
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • Youtube
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • Youtube

  • water and generalities
  • formulas and tools
  • processes and technologies
  • degremont® technologies
  • case studies
search Close
  • home
  • search

search results

refine results

all contents
all contents

filter results

cancel all filters

search results

33 results found for: Biofor do a new search
a high performance biological process - Biofor®

The Biofor® allows an advanced treatment of suspended solids (SS) and carbon and /or nitrogen pollution with no odor. The effluent to be treated is continuously fed into a biological reactor called ... Biofor, Filtration, Biolite, Wastewater, Attached growth, Biological processes ... Biofor Filtration Biolite Wastewater Attached growth Biological processes ... a high performance biological process - Biofor®...

wastewater re-use

cooling towers is performed on-site by biofiltering recycled water, a satellite treatment, which is distributed for irrigation purposes and other urban uses. Compact and high productivity Biofor ... Reuse, Biofor, Wastewater ... Reuse Biofor Wastewater...

high pressure centrifuges

Centrifugation, Biofor, Sludge treatment ... Centrifugation Biofor Sludge treatment...

anapulse (sludge blanket digester)

undergo supplementary treatment either in a large polishing lagoon (~ 20 days) or in a Biofor C + N. ... Anapulse, Methane fermentation, Biogas, Biofor ... Anapulse Methane fermentation Biogas Biofor...

treating effluent produced when removing sulfur from electricity generating plant

of construction and to prevent clogging); and requires special materials of construction; sludge treatment (thickening and dewatering). When NOx are present, a Biofor nitrification ... Densadeg, Biofor, Industrial effluent treatment ... Densadeg Biofor Industrial effluent treatment...

Xiamen wastewater treatment plant (China)

Primary clarification Fine screening Biological treatment: 2 x 7 Biofor DN: 86.5 m2 / unit 2 x 14 Biofor CN: 86.5 m2 / unit 2 x 4 aeration system - Q = 25 000 Nm3/h per line ... Flottation, Biofor, Wastewater, Biological processes, Sedipac ... Flottation Biofor Wastewater Biological processes Sedipac...

nitrogen conversion

eliminating ammonium); however the best performing machines are filled with biolite, e.g. the degremont® Nitrazur nitrificator (figure 43), a reactor similar to the Biofor Nused on wastewater and where air ... Biofor, Nitrification, Denitrification, Filtrazur, Nitrazur ... Biofor Nitrification Denitrification Filtrazur Nitrazur...

gas dissolution (absorption)

solutions that combine these two dissolution modes: e.g. iron removal columns, Nitrazur N, Biofor reactors. ... Nitrazur, Biofor, Iron removal, Oxidation, Disinfection ... Nitrazur Biofor Iron removal Oxidation Disinfection...

tertiary treatment

-flocculation with the negative impact of additional costs for reagents and processing additional sludge output; ozonation or ozonation followed by the BIOFOR (Oxyblue) which presents a number of advantages: compactness ... Biofor, Oxyblue, Industrial effluent treatment, Textile industry, Tertiary treatment ... Biofor Oxyblue Industrial effluent treatment Textile industry Tertiary treatment...

catalytic ozonation : toccata

is lower than the rate at which non-biodegradable compounds are removed. In this case, it is suggested to use catalytic ozonation in conjunction with a subsequent biological treatment (Biofor, for instance ... Ozonation, Biofor, Oxidation, Disinfection, Agri-food industry ... Ozonation Biofor Oxidation Disinfection Agri-food industry...

barscreening

; for instance, an UWW plant comprising a Densadeg followed by a Biofor, fed by a combined system, will include 80 mm preliminary barscreening, 6 mm fine barscreening and 3 mm straining. These systems can ... Biofor, Wastewater, Pretreatments, Bar screening, Densadeg ... Biofor Wastewater Pretreatments Bar screening Densadeg...

biological filters

Flopac), or by injecting air direct into the reactor (see Biofor). flopac Theprocess whereby oxygen is pre-dissolved in the water to be treated has been implemented in tertiary filtration ... Biofor, Attached growth, Biofilters, Nitrazur, Biolite, Denitrification, Oxyblue ... Biofor Attached growth Biofilters Nitrazur Biolite Denitrification Oxyblue...

advanced wastewater treatment for polishing treatment associating ozonation and biofiltration – Oxyblue™

The OxyblueTM is a tertiary treatment technology for industrial wastewater combining chemical oxidation (ozonation) and biological oxidation (biofiltration - BioforTM). It is main advantage ... Ozonation, Oxyblue, Biofor, Wastewater, Tertiary treatment, Oxidation ... Ozonation Oxyblue Biofor Wastewater Tertiary treatment Oxidation...

Sophia Antipolis wastewater treatment plant (France)

of carbon and partial treatment of constituted nitrogen Biofiltration C = 4 x existing Biofor® C + 2 additional Biofor® C to raise the capacity to 50 000 PE Biofiltration N = 4 x existing Biofor® N + 2 ... Biofiltration, Ozonation, Biofor, Densadeg, Wastewater, Micropollutants, Primary settling, Disinfection, Denitrification ... Biofiltration Ozonation Biofor Densadeg Wastewater Micropollutants Primary settling Disinfection Denitrification...

changes in limitations applicable to control-regulation systems

to the main items of equipment (see Biofor architecture solution 1 figure 7) "all in parallel"; or a redundant programmable logic controller with remote inputs/outputs and man-machine interfaces distributed ... Aquazur, Ultrazur, Ultrafiltration, Biofor, Pulsator, Centrifugation, Biofilters, Densadeg ... Aquazur Ultrazur Ultrafiltration Biofor Pulsator Centrifugation Biofilters Densadeg...

Xiamen (China) wastewater treatment plant

Biofor, Wastewater, Primary settling, Sedipac, Flotation, Disinfection, Flottation, Biological processes ... Biofor Wastewater Primary settling Sedipac Flotation Disinfection Flottation Biological processes...

influence of a plant’s environment (appearance, odours, noise): compactness

surface areas by a factor of 3 to 4, Densadeg 2D or 4D by a factor of 5 to 7) has caused traditional primary settling to become more compact; biofiltration (Biofor process) can successfully replace ... Densadeg, Biofor, Filtration, Biofiltration, Ultrafor, Sedipac, Wastewater, Primary settling, Odour Control ... Densadeg Biofor Filtration Biofiltration Ultrafor Sedipac Wastewater Primary settling Odour Control...

biological treatment

, Biofor; sludge disposition which may necessitate minimum sludge production: methane fermentation, Ultrafor, or even activated sludge with reduced sludge output (Biolysis E or O, Biocontrol). Table ... Ultrafor, Biofor, Industrial effluent treatment, Agri-food industry, Biological processes, Phosphate removal, Methane fermentation, Activated sludge, Anaerobic, Meteor ... Ultrafor Biofor Industrial effluent treatment Agri-food industry Biological processes Phosphate removal Methane fermentation Activated sludge Anaerobic Meteor...

attached growth processes

filters The Biofor is an upflow biofilter where co-current process air and water is injected via a network of fine bubble diffusers called Oxazur. Biolite is the filtering medium; its granulometry ... Attached growth, Biological processes, Biofilters, Clarification, Biofor, Greendaf, Meteor, Mixed growths ... Attached growth Biological processes Biofilters Clarification Biofor Greendaf Meteor Mixed growths...

ultra pure water used in semiconductor and pharmaceutical industries

that contains ammonia using the biological system: Biofors are used to remove the OM (mainly biodegradable alcohol) with NH4+ nitrification and denitrification, or three attached growth stages (see chapters ... Ozone, Filtration, Biofor, Industrial water treatment, Reverse Osmosis, Oxidation, Degasification, GAC ... Ozone Filtration Biofor Industrial water treatment Reverse Osmosis Oxidation Degasification GAC...

1 - 20 of 33 result(s)
  • 1
  • 2
Back to the top
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • cookies management
  • Youtube
Suez Suez

SUEZ's degremont® water handbook offers to water treatment professionals, fundamental concepts of water treatment processes and technologies as well as degremont® solutions applied to treatment line and adapted to each use of water. Designed by field men for field men, this valuable tool is essential for site managers, environmental managers, quality managers, maintenance managers, stakeholders in sustainable development, water agencies, documentation centers in universities, consultants, local authority technical departments, water management companies, etc.

Piano Analytics (Essential mode-Opt-in)

The Piano Analytics (AT Internet) audience measurement service aims to produce statistical and digital intelligence data and analyses, then to provide them via a secure web interface, or via export of this data.

When you enter to this website, the Piano Analytics (AT Internet) service is set to "essential", so that only strictly necessary information, without identifying data, can be transmitted.

When you give your consent, Piano Analytics (AT Internet) is set to "opt-in", it will process personal data.

At any time, you can choose to withdraw this consent. In this case, Piano Analytics (AT Internet) will switch back to "essential" mode.

You also have the option of activating the "opt-out" option on the legal notice page. Once in opt-out mode, no audience measurement data is collected; only a passing signal is collected by Piano Analytics (AT Internet) and returned in the "privacy - opt-out" report.

OK Prohibit
Learn more