3good reasons
to create an account
save
visualize
stay informed
create your account
save/visualize/stay informed create your account
degremont® water handbook degremont® water handbook
Menu
Close
search
Close
login
  • FR
  • EN
  • FR
  • EN
  • water and generalities
    • water: a fundamental element
    • what water should we treat ? and why ?
    • fundamental physical-chemical engineering processes applicable to water treatment
    • fundamental biological engineering processes applicable to water treatment
    • water analysis and treatability
    • aquatic organisms
    • corrosion in metal and concrete
  • formulas and tools
    • formulary
  • processes and technologies
    • pre-treatments
    • flocculators – settling tanks – flotation units
    • biological processes
    • methane fermentation
    • filters
    • using ion exchangers
    • separation by membranes
    • degasification, odour control, evaporation
    • oxidation-disinfection
    • liquid sludge treatment
    • dewatered sludge treatment
    • reagent storage and feeding
    • instrumentation control-regulation
    • drinking water treatment
    • treating municipal wastewater
    • treatment and conditioning of industrial water
    • industrial processes and effluent treatment
  • degremont® technologies
    • drinking water production
    • desalination
    • wastewater treatment
    • sludge treatment
    • air treatment
  • case studies
    • drinking water production
    • wastewater treatment
    • desalination
    • sludge treatment
  • login
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • Youtube
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • Youtube

  • water and generalities
  • formulas and tools
  • processes and technologies
  • degremont® technologies
  • case studies
search Close
  • home
  • search

search results

refine results

all contents
all contents

filter results

cancel all filters

search results

16 results found for: Ion exchange do a new search
main types of ion exchangers

ion exchanger characteristic In order to be industrially applicable, an ion exchanger needs to meet a range of requirements: it must discharge the least possible polymerisation residue ... Ion exchange ... main types of ion exchangers...

water blocking

Historically, water blocking was the first process used. The regenerant solution is injected at the base of the ion exchanger resin bed; while a stream of blocking water is introduced at the top ... Ion exchange...

conventional applications

Ion exchange treatment is used for: Demineralised water production for industrial processes, whether for industrial product manufacturing processes or in steam generator supply ... Ion exchange...

air blocking

Ion exchange...

general

principle Ion exchangers are insoluble granular substances; their molecular structures include acid or base radicals capable of permutating, without any visible change to their physical appearance ... Ion exchange...

elimination of organic matter

The various ion exchange methods presented previously assume that the raw water contains only dissolved minerals. In reality, natural water always contains a certain amount of organic matters ( OM ... Ion exchange...

various line options

The block diagram in figure 89 shows the combinations most commonly found in demineralisation. These combinations will be examined in greater depth in chapter using ion exchangers. Figure 89 ... Demineralisation Ion exchange...

mechanical blocking

other processes In the Liftbett process, the ion exchanger unit is divided into two superimposed chambers, separated by a plate (3) fitted with twin head nozzles (figure 5). The upper compartment ... Ion exchange...

demineralisation line calculation principle

, in m³, including process water if applicable; hourly output Q in m³/h; resin exchange capacity C expressed in French degrees per litre of compacted resin. (Degrees can be replaced ... Demineralisation Ion exchange...

operation and maintenance of a total demineralisation unit

resins); resin pores poisoned internally (especially with anion exchangers). There are two types of remedies; however, these must never be applied before consulting a specialist : preventive ... Demineralisation Ion exchange...

classic schemes used

We must emphasise that ion exchange processes must only be used after a pre-treatment adapted to each grade of raw water and especially including the removal of suspended solids, organic matter ... Ion exchange Carbonate removal Demineralisation...

radioactivity

-flocculation, lime precipitation, filtration through GAC, ion exchanges or reverse osmosis … (see radioactivity). ... Filtration Drinking water Reverse Osmosis GAC Coagulation-flocculation Ion exchange...

special applications

Water treatment is not the only area in which ion exchangers are used; they are a practical and efficient means of solving many chemical engineering problems. The liquids to be treated can ... Demineralisation Ion exchange Industrial effluent treatment...

internal treatments or specific pre-treatments

Flottation Filtration Adsorption Ultrafor Microfiltration Nanofiltration Industrial effluent treatment Chemical industries Settling Flotation Oxidation Reverse Osmosis Ion exchange Aerobic Anaerobic...

treating make-up water

with treatments over resin and/or membrane that are essential for guaranteeing the requisite chemical quality. Additionally, using ion exchangers and separation by membranes describe the various technologies ... Clarification Filtration Demineralisation Industrial water Carbonate removal Reverse Osmosis Ion exchange Degasification Industrial water treatment...

agri-food industries

pesticides); final chlorination; demineralization using ion exchanges for boiler feed water. A more modern system that does not create pollution (no saline discharge) will include : river water ... Denitratation Nanofiltration Ozonation Demineralisation Industrial water treatment Carbonate removal Manganese removal Nitrate removal Reverse Osmosis Sand filtration Chlorination Ion exchange GAC...

1 - 16 of 16 result(s)
Back to the top
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • cookies management
  • Youtube
Suez Suez

SUEZ's degremont® water handbook offers to water treatment professionals, fundamental concepts of water treatment processes and technologies as well as degremont® solutions applied to treatment line and adapted to each use of water. Designed by field men for field men, this valuable tool is essential for site managers, environmental managers, quality managers, maintenance managers, stakeholders in sustainable development, water agencies, documentation centers in universities, consultants, local authority technical departments, water management companies, etc.

Piano Analytics (Essential mode-Opt-in)

The Piano Analytics (AT Internet) audience measurement service aims to produce statistical and digital intelligence data and analyses, then to provide them via a secure web interface, or via export of this data.

When you enter to this website, the Piano Analytics (AT Internet) service is set to "essential", so that only strictly necessary information, without identifying data, can be transmitted.

When you give your consent, Piano Analytics (AT Internet) is set to "opt-in", it will process personal data.

At any time, you can choose to withdraw this consent. In this case, Piano Analytics (AT Internet) will switch back to "essential" mode.

You also have the option of activating the "opt-out" option on the legal notice page. Once in opt-out mode, no audience measurement data is collected; only a passing signal is collected by Piano Analytics (AT Internet) and returned in the "privacy - opt-out" report.

OK Prohibit
Learn more