3good reasons
to create an account
save
visualize
stay informed
create your account
save/visualize/stay informed create your account
degremont® water handbook degremont® water handbook
Menu
Close
search
Close
login
  • FR
  • EN
  • FR
  • EN
  • water and generalities
    • water: a fundamental element
    • what water should we treat ? and why ?
    • fundamental physical-chemical engineering processes applicable to water treatment
    • fundamental biological engineering processes applicable to water treatment
    • water analysis and treatability
    • aquatic organisms
    • corrosion in metal and concrete
  • formulas and tools
    • formulary
  • processes and technologies
    • pre-treatments
    • flocculators – settling tanks – flotation units
    • biological processes
    • methane fermentation
    • filters
    • using ion exchangers
    • separation by membranes
    • degasification, odour control, evaporation
    • oxidation-disinfection
    • liquid sludge treatment
    • dewatered sludge treatment
    • reagent storage and feeding
    • instrumentation control-regulation
    • drinking water treatment
    • treating municipal wastewater
    • treatment and conditioning of industrial water
    • industrial processes and effluent treatment
  • degremont® technologies
    • drinking water production
    • desalination
    • wastewater treatment
    • sludge treatment
    • air treatment
  • case studies
    • drinking water production
    • wastewater treatment
    • desalination
    • sludge treatment
  • login
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • Youtube
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • Youtube

  • water and generalities
  • formulas and tools
  • processes and technologies
  • degremont® technologies
  • case studies
search Close
  • home
  • search

search results

refine results

all contents
all contents

filter results

cancel all filters

search results

13 results found for: Ultraviolet disinfection do a new search
disinfection

) of an Escherichia coli population; more generally, sections oxidation and disinfection using chlorine, oxidation and disinfection using chlorine dioxide, oxidation and disinfection using ozone and ultraviolet ... Ozone, Drinking water, Surface water, Disinfection, Chlorine, Ultraviolet disinfection ... Ozone Drinking water Surface water Disinfection Chlorine Ultraviolet disinfection ... disinfection ... Oxidation/Disinfection...

safety and environment

The area surrounding the UV disinfection channel must be protected as to avoid direct and unprotected access. Eyes and skin must be protected against UV radiation. ... Disinfection, Ultraviolet disinfection ... Disinfection Ultraviolet disinfection ... Oxidation/Disinfection...

the different types of UV sources

Disinfection, Ultraviolet disinfection ... Disinfection Ultraviolet disinfection ... Oxidation/Disinfection...

regulation and controls

control devices In order to maintain proper disinfection performance UV disinfection systems are equipped with control features that also help with system maintenance. They include: a lamp ... Disinfection, Ultraviolet disinfection ... Disinfection Ultraviolet disinfection ... Oxidation/Disinfection...

the bioassay (biological test)

bacteriophages Figure 34. UV collimator The second stage of the Bioassay is carried out on site. It consists of measuring the effectiveness of a disinfection system for different flow rates, using ... Disinfection, Ultraviolet disinfection ... Disinfection Ultraviolet disinfection ... Oxidation/Disinfection...

reactors used in drinking water applications

(see also disinfection) installation conditions Transmittance should be equal to or better than 85%. This condition determines the nature of pre-treatment to apply. reactor types and layout ... Disinfection, Ultraviolet disinfection ... Disinfection Ultraviolet disinfection ... Oxidation/Disinfection...

basic principles – terminology

terminology Inactivation: difference between the number of micro-organisms present before and after disinfection. Abatement is usually expressed in common logarithms. Ballast : electromagnetic and ... Disinfection, Ultraviolet disinfection ... Disinfection Ultraviolet disinfection ... Oxidation/Disinfection...

reactors used in wastewater applications

installation conditions A pretreatment stage to UV disinfection is essential and with the exception of very diluted effluents, this pretreatment should include a biological treatmentand a tertiary ... Disinfection, Ultraviolet disinfection ... Disinfection Ultraviolet disinfection ... Oxidation/Disinfection...

sizing principles

delivered by the disinfection system is expressed as follows: lamp life-end factor Fp The output emitted by a lamp declines with increasing operating hours. This phenomenon results from the oxidation ... Disinfection, Ultraviolet disinfection ... Disinfection Ultraviolet disinfection ... Oxidation/Disinfection...

reactors and industrial water applications

They are most commonly found in the field of disinfection : pure and ultra pure water whether or not used in conjunction with UV oxidation; wash water in agri-food applications; cooling ... Disinfection, Ultraviolet disinfection, Agri-food industry ... Disinfection Ultraviolet disinfection Agri-food industry ... Oxidation/Disinfection...

Saint-Michel-Chef-Chef wastewater treatment plant (France)

Ultrafiltration Ultrafor Centrifugation Greenbass Wastewater Pretreatments Ultraviolet disinfection ... Sludge dewatering Filters Oxidation/Disinfection Pretreatment Biological processes...

special case of municipal WW disinfection

Wastewater disinfection is becoming increasingly necessary, especially in the following cases: discharging into public swimming areas (river, lake or sea); discharging into oyster ... Biofor, Filtration, Ultrafor, Ozone, Nitrification, Wastewater, Disinfection, Ultraviolet disinfection, Primary settling, Chlorination, Biofilters, Activated sludge, Denitrification ... Biofor Filtration Ultrafor Ozone Nitrification Wastewater Disinfection Ultraviolet disinfection Primary settling Chlorination Biofilters Activated sludge Denitrification ... special case of municipal WW disinfection ... Filters Flocculation/Sedimentation/Flotation Oxidation/Disinfection Biological processes...

quality and reliability objectives

and shellfish farms and where there are public swimming beaches (in these cases, disinfection is essential for abating contaminating bacteriological micro-organisms). The plant then has to be supplemented ... Reuse, Ozone, Wastewater, Disinfection, Ultraviolet disinfection ... Reuse Ozone Wastewater Disinfection Ultraviolet disinfection...

1 - 13 of 13 result(s)
Back to the top
  • about us
  • help
  • site map
  • legal notice
  • contact
  • authors
  • cookies management
  • Youtube
Suez Suez

SUEZ's degremont® water handbook offers to water treatment professionals, fundamental concepts of water treatment processes and technologies as well as degremont® solutions applied to treatment line and adapted to each use of water. Designed by field men for field men, this valuable tool is essential for site managers, environmental managers, quality managers, maintenance managers, stakeholders in sustainable development, water agencies, documentation centers in universities, consultants, local authority technical departments, water management companies, etc.

Piano Analytics (Essential mode-Opt-in)

The Piano Analytics (AT Internet) audience measurement service aims to produce statistical and digital intelligence data and analyses, then to provide them via a secure web interface, or via export of this data.

When you enter to this website, the Piano Analytics (AT Internet) service is set to "essential", so that only strictly necessary information, without identifying data, can be transmitted.

When you give your consent, Piano Analytics (AT Internet) is set to "opt-in", it will process personal data.

At any time, you can choose to withdraw this consent. In this case, Piano Analytics (AT Internet) will switch back to "essential" mode.

You also have the option of activating the "opt-out" option on the legal notice page. Once in opt-out mode, no audience measurement data is collected; only a passing signal is collected by Piano Analytics (AT Internet) and returned in the "privacy - opt-out" report.

OK Prohibit
Learn more